Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Pesqui. bras. odontopediatria clín. integr ; 17(1): e2918, 13/01/2017. tab, graf
Article in English | LILACS, BBO | ID: biblio-914287

ABSTRACT

Objective: To compare the bond strength of three-step and self-etch adhesive systems with and without prior acid etching on bonding of fiberglass posts in root canals. Material and Methods: Experiments were conducted on roots of five upper molars without curvature and sectioned in a cervical-apical direction. With the aid of a highspeed turbine and diamond tips, cylindrical cavities 7 mm in depth and 1.4 mm in diameter were made in the dentine. The roots of the same tooth were used, where the retainers were cemented, thus generating three groups: Group A: Adper Scotchbond Multipurpose Plus (SBMP) + Rely X ARC; Group B: Single Bond Universal (SBU-1) + Rely X ARC, with acid etching prior to adhesive insertion; Group C: Single Bond Universal (SBU-2) + Rely X ARC. The samples were stored in a bacteriological incubator at 37ºC with 100% humidity for 48h and were subsequently cross-sectioned to obtain 3 dentine discs 1mm in thickness. Forty-five specimens were subjected to the push-out test. Results: Through the analysis of variance and Tukey's test, it was found that SBMP showed, with statistical significance (p<0.05), highest bond strength when compared with the SBU-1 and SBU-2 systems. The observed difference in the discs was located in the cervical portion. Conclusion: The three-step adhesive system had higher bond strength with the substrate than the self-etching adhesive only in the disc in the cervical portion; further, statistically, the prior application of phosphoric acid in SBU-1 did not affect its bond strength significantly.


Subject(s)
Acid Etching, Dental/methods , Dental Cements , Glass Ionomer Cements/chemistry , Tensile Strength , Analysis of Variance , Brazil , Dental Pins
2.
Braz. dent. j ; 27(5): 492-496, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: biblio-828031

ABSTRACT

Abstract Bis-acryl resins are used for temporary dental restorations and have shown advantages over other materials. The aim of this work was to evaluate the in vitro cytotoxicity of two bis-acryl composite resins (Protemp 4 and Luxatemp Star), obtained at 1, 7 and 40 days after mixing the resin components, using a standardized assay employing human primary cells closely related to oral tissues. Human gingival fibroblast cell cultures were exposed for 24 h to either bis-acryl composite resins, polystyrene beads (negative control) and latex (positive control) extracts obtained after incubation by the different periods, at 37 °C under 5% CO2. Cell viability was evaluated using a multiparametric procedure involving sequential assessment (using the same cells) of mitochondrial activity (XTT assay), membrane integrity (neutral red test) and total cell density (crystal violet dye exclusion test). The cells exposed to the resin extracts showed cell viability indexes exceeding 75% after 24 h. Even when cells were exposed to extracts prepared with longer conditioning times, the bis-acryl composite resins showed no significant cytotoxic effects (p>0.05), compared to the control group or in relation to the first 24 h of contact with the products. There were no differences among the results obtained for the bis-acryl composite resins evaluated 24 h, 7 days and 40 days after mixing. It may be concluded that the bis-acryl resins Protemp 4 and Luxatemp Star were cytocompatible with human gingival fibroblasts, suggesting that both materials are suitable for use in contact with human tissues.


Resumo Resinas bisacrílicas são usadas em restaurações dentárias provisórias e têm mostrado vantagens em relação a outros materiais. O objetivo deste trabalho foi avaliar a citotoxicidade in vitro de duas resinas compostas bisacrílicas (Protemp 4 e Luxatemp Star), obtidas após 1, 7 e 40 dias da mistura com os componentes da resina, usando um ensaio padronizado empregando células primárias humanas fortemente relacionadas aos tecidos orais. Culturas de células de fibroblastos gengivais humanos foram expostas por 24 h aos extratos das resinas bisacrílicas, esferas de poliestireno (controle negativo) e látex (controle positivo), obtidos após diferentes períodos de incubação, a 37 °C e com 5% CO2. A viabilidade celular foi avaliada usando procedimentos multiparamétricos que envolvem a avaliação sequencial (usando as mesmas células) da atividade mitocondrial (ensaio XTT), a integridade de membrana (teste do vermelho neutro) e a densidade celular total (teste de exclusão do corante cristal violeta). As células expostas aos extratos mostraram viabilidade celular acima de 75% depois de 24 h. Mesmo quando as células foram expostas aos extratos com aumento do tempo de condicionamento, as resinas bisacrílicas não apresentaram efeitos citotóxicos significativos (p<0,05), comparadas ao grupo controle ou em relação às primeiras 24 h de contato com os produtos. Não houve diferença entre os resultados obtidos para as resinas bisacrílicas avaliadas entre as 24 h, 7 e 40 dias depois da mistura. Concluímos que as resinas bisacrílicas Protemp 4 e Luxatemp Star foram citocompatíveis com os fibroblastos gengivais humanos, sugerindo que ambos materiais são adequados para uso em contato com tecidos humanos.


Subject(s)
Humans , Composite Resins , Gingiva/cytology , Fibroblasts/cytology
3.
Rev. dental press estét ; 10(1): 79-88, jan.-mar .2013. ilus
Article in Portuguese | LILACS | ID: lil-681621

ABSTRACT

Para o sucesso do tratamento odontológico, é fundamental realizar um correto diagnóstico, planejamento e execução do trabalho. Os materiais utilizados para restaurações provisórias são de grande importância na reabilitação estética anterior, pois são os guias para escolha da cor, forma e contorno da restauração final, proporcionando maior previsibilidade do resultado, tanto para o paciente quanto para o profissional. As resinas provisórias bisacrílicas tornaram-se uma escolha cada vez mais popular devido às suas melhores propriedades mecânicas, resultados estéticos e facilidade de manuseio. O presente artigo objetiva demonstrar um caso clínico onde foi utilizada resina bisacrílica para reabilitação estética provisória. Tal técnica propiciou a esse caso um satisfatório resultado parcial funcional e estético, respeitando os anseios da paciente e facilitando o sucesso final do trabalho


Introduction: For the success of dental treatment it is vital a correct diagnosis, planning and execution of work. The materials used for provisional restorations are of great importance in the anterior esthetic rehabilitation, as they are guides for choosing the color, shape and contour of the fnal restoration, proportionating greater predictability of the outcome for both patient and professional. The provisional bisacryl composite became an increasingly popular choice due to its better mechanical properties, cosmetic results and ease of handling. Objective: This article aims to demonstrate a clinical case in which it was used a bis-acrylic resin for provisional esthetic rehabilitation. Conclusion: This technique used in this case provided a satisfactory partial result, as functional as esthetic, respecting the wishes of the patient and facilitating the ultimate success of the work.


Subject(s)
Humans , Female , Adult , Dental Materials , Dental Prosthesis , Dental Restoration, Temporary , Dental Veneers , Esthetics, Dental , Mouth Rehabilitation
4.
Rev. flum. odontol ; 17(36): 53-58, jul.-dez. 2011. graf
Article in Portuguese | LILACS, BBO | ID: lil-638429

ABSTRACT

O objetivo deste trabalho foi avaliar as alterações dimensionais de moldes de alginato quando se emprega a técnica de reembasamento.A partir de um modelo padrão em aço inoxidável, contendo duas marcações, foram realizadas moldagens com AlginatoEzactKromm (Vigodent) e os modelos de gesso foram confeccionados com o gesso tipo IV Durone (Dentsply). As moldagensforam divididas em 2 grupos: Grupo I – 10 moldagens com alginato sem reembasamento e; Grupo II – 10 moldagens com o alginatoutilizando o reembasamento. Os modelos de gesso foram confeccionados com espatulação a vácuo e levados ao Microscópio Comparador Mitutoyo para obtenção das medidas que foram comparadas com o modelo padrão de aço inoxidável. Os dados foram submetidos a análise estatística através do teste “t” de Student e obtivemos os seguintes resultados: houve alteração dimensional estatisticamente significante no Grupo II (p<0,05) em comparação com o Grupo I e o modelo padrão. Concluiu-se que não é recomendado a realização da técnica de reembasamento em moldagem com Alginato, devido a alteração dimensional observada.


The aim of this study was to evaluate the dimensional changes in alginate molds when employing the technique of relining. Froma standard stainless steel, with two appointments were made with alginate impressions EzactKromm (Vigodent) and plaster casts were made of gypsum type IV Durone (Dentsplay). The casts were divided into two groups: Group I – 10 impressions without relining and Group II – 10 inpressions with alginate using the relining. The plaster casts were made with vacuum mixing and taken to the Comparator Mitutoyo Microscope to obtain measures that were compared with the standard model of stainless steel. The data were statistically analyzed by t test of Student and obtained the following results: there was a statistically significant dimensional changes in Group II (p <0.05) compared with Group I and the standard model. It was concluded that it is not recommended to perform the technique of relining impression with alginate in, because the dimensional changes observed.


Subject(s)
Dental Impression Materials , Dentistry
5.
Rev. dental press estét ; 8(2): 66-76, abr.-jun. 2011. ilus
Article in Portuguese | LILACS, BBO | ID: lil-594769

ABSTRACT

O tratamento estético utilizando o clareamento dentário e restaurações com resina composta é uma excelente alternativa para a obtenção de um belo sorriso. A procura da estética pelos pacientes tem sido cada vez mais frequente, em busca de dentes claros e de um sorriso harmonioso. O clareamento dentário proporciona uma estética mais favorável, porém já é bastante elucidado que os agentes clareadores atuam somente na estrutura dentária, e não nos materiais restauradores, no que diz respeito à descoloração. Por isso, muitas vezes há a necessidade de substituir restaurações de resina composta após o tratamento clareador. O presente artigo apresenta o relato de um caso clínico em que foi realizado o clareamento dentário em consultório com peróxido de hidrogênio a 20 por cento com posterior substituição das restaurações de resina composta pela técnica estratificada, utilizando um compósito mecrohíbrido. O resultado clínico foi adequado e satisfatório, oferecendo um belo sorriso ao paciente, o que demonstra a possibilidade de se realizar os dois procedimentos, visando melhorar a estética, através de um sorriso harmonioso.


The esthetic treatment using dental bleaching and resin composite restorations is an excellent alternative to obtain a beautiful smile. Patients' demands for cosmetic have been much more often in search of bleached teeth and a bright harmonic smile. Dental bleaching provides a beautiful smile, but it is quite known that bleaching agents act only in the tooth structure and do not in restorative materials. Therefore, there is often the need to replace resin composite restorations after bleaching. This article presents a case report in which was performed a dental office bleaching with hydrogen peroxide at 20%, with subsequent replacement of resin composite restorations through the stratified technique using a micro-hybrid resin composite. Clinical outcome was adequate and satisfactory offering a beautiful smile to the patient. This demonstrates the possibility of performing both procedures, and therefore improve esthetics as the proportion of a harmonious smile.


Subject(s)
Humans , Female , Young Adult , Composite Resins , Esthetics , Tooth Bleaching , Esthetics, Dental
6.
Rev. flum. odontol ; 17(35): 36-40, jan.-jun. 2011. graf
Article in Portuguese | LILACS, BBO | ID: lil-638415

ABSTRACT

O objetivo deste trabalho foi avaliar o escoamento do cimento fosfato de zinco como agente de fixação. Foram utilizados dois cimentos de fosfato de zinco, o Cimento LS (Vigodent) e o Cimento de Zinco (SS White). Todos os cimentos foram testados de acordo com base na Especificação nº 8 da ADA, para o cimento fosfato de zinco. Após a manipulação, uma seringa BD com a ponta recortada foi utilizada para dispensar um volume de 0,5 ml sobre uma placa de vidro quadrangular de superfície lisa, com as dimensões 10 cm x 10 cm. Decorrido três minutos do início da manipulação, outra placa de vidro com dimensões 5 cm x 5 cm pesando 20 gramas e um peso adicional de 100 gramas foram colocados sobre a mistura de cimento, totalizando uma carga de 120 gramas. O peso foi removido dez minutos após o início da manipulação e o disco formado pelo cimento endurecido foi medido em seus diâmetros maior e menor utilizando um paquímetro eletrônico digital Starrett. Para o teste de consistência ou de escoamento cada cimento foi avaliado cinco vezes e os dados obtidos foram aproximados para o milímetro mais próximo. Os valores obtidos foram anotados e essas medidas foram somadas e divididas por dois para a obtenção de um diâmetro médio. Os valores foram submetidos à análise estatística através do teste “t” de Student e os resultados foram os seguintes: os maiores valores do diâmetro do círculo formado pelo cimento foram obtidos no Cimento LS (Vigodent) (p<0,05). Concluiu-se que o Cimento Fosfato de Zinco LS (Vigodent) apresentou maior escoamento em comparação com o Cimento de Zinco (SS White).


The aim of this study was to evaluate the flow of zinc phosphate cement as a fixing agent. We used two zinc phosphate cement, Cement LS (Vigodent) and Zinc cement (SS White). All cements were tested according to specification based on paragraph 8 of the ADA, for the zinc phosphate cement. After manipulation, a BD syringe with the tip cut was used to dispense a volume of 0.5 ml of a square glass plate with a smooth surface, with the dimensions 10 cm x 10 cm. Three minutes elapsed from the beginning of the manipulation, another glass plate with dimensions 5 cm x 5 cm and weighing 20 grams extra weight to 100 grams were weight placed on the cement mixture, with a total load of 120 grams. The weight was removed ten minutes after the start of the manipulation and the disk formed by the hardened cement was measured in its largest and smallest diameters using a digital caliper Starrett. To test the consistency or flow each cement was assessed five times and the data were approximated to the nearest millimeter. The values were recorded and these measures were summed and divided by two to obtain an average diameter. The values were statistically analyzed by "t" test of Student and the results were as follows: the highest values of the diameter of the circle formed by the cement were obtained in LS Cement (Vigodent) (p <0.05). It was concluded that zinc phosphate cement LS (Vigodent) showed greater flow in comparison with zinc cement (White SS).


Subject(s)
Dental Cements , Surface Runoff
7.
Rev. flum. odontol ; 16(34): 36-42, jul.-dez. 2010. graf
Article in Portuguese | LILACS, BBO | ID: lil-605629

ABSTRACT

O objetivo desse trabalho foi identificar contaminação em moldes, assim como, estabelecer a eficácia da solução desinfetante para utilização nas clínicas da FOCampos. Foram usadas 176 moldagens obtidas de pacientes da FOCampos, nas quais foi realizada a coleta do material utilizando dois “swabs” em solução salina. Logo em seguida à remoção do molde da boca e ser lavado com água corrente, foi feita a primeira coleta com o “swab” passado na superfície do molde e em seguida introduzido na salina. A seguir, foi realizada a desinfecção do molde com hipoclorito de Na a 1% sob a forma de aerossol e colocado em plástico auto-adesivo por 10 minutos. Terminando o tempo e após a lavagem do molde, nova coleta foi feita. Ambos os “swabs” foram introduzidos em tubos de ensaio com o meio tioglicolato, e incubados por 72 horas à 37oC. Após este período, foi observada a turvação pela inspeção visual considerando os escores (0 = ausência de turvação; + = turvação discreta; ++ = turvação moderada; +++ = turvação intensa). Os dados foram submetidos a uma análise estatística descritiva para a obtenção dos seguintes resultados: na primeira coleta, 73,86% dos moldes apresentaram leve contaminação; 15,91% moderada, 7,95% intensa e 2,27% não apresentaram contaminação. Após a desinfecção, na segunda coleta, 95,45% dos moldes não apresentaram contaminação; 3,98% discreta contaminação e 0,57% moderada. Pode-se concluir que houve contaminação em todas as moldagens obtidas; a desinfecção foi eficaz na maioria das moldagens e o procedimento deve ser adotado rotineiramente nas clínicas da FOCampos.


The aim of this study was to identify contamination in molds, as well as establish the efficacy of disinfectant solution for use in clinical FOCampos. One hundred and seventy-sic impressions were used from patients of FOCampos, in which was collected the material using two swabs in saline. Soon after the removal of the casto f the mouth and washed with water, was made the first collection with the swab past the surface of the mold and then inserted into the saline. They were then carried out disinfection of the mold with sodium hypochlorite at 1% in the formo f aerosol and placed in plastic self-adhesive for 10 minutes. After the time and after washing of the mold, the new collection was made. Both swabs were placed in test tubes with thioglycolate middle and incubated for 72 hours at 37oC. After this period, the turbidity was observed by visual inspection considering the scores (0 = no haze; + = slight turbidity, turbidity ++ = moderate +++ = intense turbidity). Data were subjected to descriptive statistical analysis to obtain the following results: the first collection, 73.86% of the molds showed slight contamination, 15.91% moderate, severe 7.95% and 2.27% were not contaminated. After disinfection, the second test, 95.45% of templates were not contaminated, 3.98% and 0.57% discreet moderate contamination. It can be concluded that there was contamination in all the moldings obtained, the disinfection was effective in most casts and the procedure should be adopted routinely in clinical FOCampos.


Subject(s)
Dental Clinics , Disinfection , Models, Anatomic
8.
Rio de Janeiro; s.n; 2008. 107 p. ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-866138

ABSTRACT

O objetivo deste estudo foi comparar, por meio de mensuração das fendas na interface dentina - restauração de resina composta com utilização de algumas variáveis: fotoativação com lâmpada halógena e com LED; utilização de resina microhíbrida com partículas nanométricas Filtek Z350 ou sem estas partículas Filtek Z250; variação do sistema adesivo (Adper Single Bond 2 ou Adper Scotchbond Multi Purpose); variação da temperatura da resina composta; uso de dessensibilizante dentinário ou não; remoção do colágeno da dentina ou não e variação da intensidade de luz na fotoativação. Foram utilizados 70 molares humanos recém-extraídos, com cavidades circulares na dentina superficial de cada face proximal, foram divididos em 10 amostras para cada variável citada acima. Os dentes foram devidamente restaurados, seguindo as instruções dos fabricantes, para todos os grupos e mantidos em estufa bacteriológica por um período de 7 dias, após este período, foram polidos e as réplicas de resina epoxídica foram confeccionadas a partir de uma moldagem com silicone por adição, as mesmas foram levadas ao MEV, para a análise. As fendas foram mensuradas com o auxílio do software UTHSCSA Image tool e os dados foram submetidos à análise estatística pelo teste “t” de Student para a obtenção dos resultados. Com base nos resultados obtidos pode-se concluir que: os menores valores de fendas marginais foram obtidos quando da utilização de luz halógena (t=3,246 e p= 0,02) e com variação da intensidade desta luz (t= - 8,808 e p= 0,00). Os menores valores relativos de fendas, mas sem diferença estatística significante, foram encontrados, também, quando a resina Filtek Z350 foi comparada com a resina Filtek Z250 (t=-0,426 e p= 0,672) e quando o adesivo Adper Scotchbond Multi Purpose foi comparado com o Sistema Adper Single Bond 2 (t= 0,883 e p= 0,382). Os maiores valores de fendas marginais foram obtidos com a resina Filtek Z350 préaquecida a 60oC (t= -3,961 e p=0,000); com o uso de ...


The objective of this study was to compare through the cracks measurements in the dentin – resin interface, using some variables: light activation with halogenic lamp and with LED; the use of micro-hybrid resin with or without nanofiller (Filtek Z350 anda Filtek Z250); variation of the adhesive systems (Adper Single Bond 2 or Scotchbond Multi Purpose); variation of the temperature in the compound resin; to use or not use the dentin desensitizing; to remove or not the dentin collagen and the light intensity variation in the light-curing. It was used 70 human extracted molars, with circular cavities in the superficial dentin of each proximal face; they were divided in 10 samples to each supra cited variable. The teeth were restored, followint the manufacturer instructions, and they were kept in a bacteriologtical kiln during a seven days period. After this time, the teeth were glossed, the resin replica were made from an addition silicone casting and these were took to the MEV, to be analyzed. The cracks were measured with the help of a UTHSCSA tool image software and the data were submited to an statistical analysis with the Student t test. The results obtained give the following conclusions: the lower values of marginal cracks were obtained when it was used the halogenic light (t = 3,246 and p = 0,02) and due the intensity variation of this light (t = 8,808 and p = 0,00). The lowest values related to the cracks were found when the Filtek Z350 resin was compared to the Filtek Z250 resin (t = 0,426 and p = 0,672), and when the Adper Scotchbond Multipurpose adhesive was compared with the Adper Single Bond 2 system (t = 0,883 and p = 0,382). The greatest values of marginal cracks were obtained with Filtek Z350 resin preheated at 60 degrees (t = -3,961 and p = 0,00); with the use of dentin desensitizing (t = -3,062 and p = 0,004) and with the removal of the collagen by using sodium hypochlorite (t = -8,808 and p = 0,000). (AU)


Subject(s)
Humans , Composite Resins , Dental Marginal Adaptation , Dental Restoration, Permanent , Curing Lights, Dental , Dental Cements , Dentin , Microscopy, Electron, Scanning , Molar
9.
Rio de Janeiro; s.n; 2008. 107 p. ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-673669

ABSTRACT

O objetivo deste estudo foi comparar, por meio de mensuração das fendas na interface dentina - restauração de resina composta com utilização de algumas variáveis: fotoativação com lâmpada halógena e com LED; utilização de resina microhíbrida com partículas nanométricas Filtek Z350 ou sem estas partículas Filtek Z250; variação do sistema adesivo (Adper Single Bond 2 ou Adper Scotchbond Multi Purpose); variação da temperatura da resina composta; uso de dessensibilizante dentinário ou não; remoção do colágeno da dentina ou não e variação da intensidade de luz na fotoativação. Foram utilizados 70 molares humanos recém-extraídos, com cavidades circulares na dentina superficial de cada face proximal, foram divididos em 10 amostras para cada variável citada acima. Os dentes foram devidamente restaurados, seguindo as instruções dos fabricantes, para todos os grupos e mantidos em estufa bacteriológica por um período de 7 dias, após este período, foram polidos e as réplicas de resina epoxídica foram confeccionadas a partir de uma moldagem com silicone por adição, as mesmas foram levadas ao MEV, para a análise. As fendas foram mensuradas com o auxílio do software UTHSCSA Image tool e os dados foram submetidos à análise estatística pelo teste “t” de Student para a obtenção dos resultados. Com base nos resultados obtidos pode-se concluir que: os menores valores de fendas marginais foram obtidos quando da utilização de luz halógena (t=3,246 e p= 0,02) e com variação da intensidade desta luz (t= - 8,808 e p= 0,00). Os menores valores relativos de fendas, mas sem diferença estatística significante, foram encontrados, também, quando a resina Filtek Z350 foi comparada com a resina Filtek Z250 (t=-0,426 e p= 0,672) e quando o adesivo Adper Scotchbond Multi Purpose foi comparado com o Sistema Adper Single Bond 2 (t= 0,883 e p= 0,382). Os maiores valores de fendas marginais foram obtidos com a resina Filtek Z350 préaquecida a 60oC (t= -3,961 e p=0,000); com o uso de...


The objective of this study was to compare through the cracks measurements in the dentin – resin interface, using some variables: light activation with halogenic lamp and with LED; the use of micro-hybrid resin with or without nanofiller (Filtek Z350 anda Filtek Z250); variation of the adhesive systems (Adper Single Bond 2 or Scotchbond Multi Purpose); variation of the temperature in the compound resin; to use or not use the dentin desensitizing; to remove or not the dentin collagen and the light intensity variation in the light-curing. It was used 70 human extracted molars, with circular cavities in the superficial dentin of each proximal face; they were divided in 10 samples to each supra cited variable. The teeth were restored, followint the manufacturer instructions, and they were kept in a bacteriologtical kiln during a seven days period. After this time, the teeth were glossed, the resin replica were made from an addition silicone casting and these were took to the MEV, to be analyzed. The cracks were measured with the help of a UTHSCSA tool image software and the data were submited to an statistical analysis with the Student t test. The results obtained give the following conclusions: the lower values of marginal cracks were obtained when it was used the halogenic light (t = 3,246 and p = 0,02) and due the intensity variation of this light (t = 8,808 and p = 0,00). The lowest values related to the cracks were found when the Filtek Z350 resin was compared to the Filtek Z250 resin (t = 0,426 and p = 0,672), and when the Adper Scotchbond Multipurpose adhesive was compared with the Adper Single Bond 2 system (t = 0,883 and p = 0,382). The greatest values of marginal cracks were obtained with Filtek Z350 resin preheated at 60 degrees (t = -3,961 and p = 0,00); with the use of dentin desensitizing (t = -3,062 and p = 0,004) and with the removal of the collagen by using sodium hypochlorite (t = -8,808 and p = 0,000).


Subject(s)
Humans , Composite Resins , Dental Marginal Adaptation , Dental Restoration, Permanent , Curing Lights, Dental , Dental Cements , Dentin , Microscopy, Electron, Scanning , Molar
SELECTION OF CITATIONS
SEARCH DETAIL